An interior beam supporting a floor can carry wind-induced forces without being exposed to the exterior. The key is to identify which portion of the roof transfers load to it and to check, segment by segment, how that force continues to the foundation.
The Question That Started the Discussion
In a public ASCE Collaborate discussion, Jason Burby described a specific case: a second-level beam supports the floor and, through columns, also receives the reactions from roof trusses. His question concerned how to determine the vertical wind-induced forces transferred to the beam: should they be calculated using the main wind force resisting system (MWFRS) procedure or the components and cladding (C&C) procedure? The answer matters for both the beam and its connections.
Two Checks, One Building
Analysis of the main system considers how wind actions are transferred through the structure as a whole. A components and cladding check considers how an individual element, such as a cladding panel or its fasteners, responds to the pressure applicable to its zone and the area specified by the procedure. ASCE/SEI 7-22 establishes design loads and load combinations; the discussion refers to its components and cladding chapter, but the comments do not replace the applicable edition or its corrections.
To understand the case, first sketch the roof covering, its fasteners, the trusses, the columns receiving their reactions, and the transfer beam. Continue tracing the path through the supports, anchors, and foundation. Then check which connections would need to transfer tension if a load combination produces uplift. A gravity-load flexural check does not answer that question.
Figure 9-6 of FEMA's Coastal Construction Manual illustrates this principle of continuity. Its construction details cannot be transferred unchanged to a metal roof or a project in Mexico.
What to Bring to a Project Review in Mexico
The declaration of validity for NMX-C-567-1-ONNCCE-2020 distinguishes between wind effects on the structure and checks of secondary elements, facades, and roofs. It also states that local requirements must be followed when they are more stringent. Before performing calculations, confirm the code and standards governing the site. Do not adopt wind speeds, coefficients, or area rules from another document without verifying their applicability.
A practical review can begin with three deliverables: a load-path sketch, a table of roof reactions for each wind load case, and a list of connections with the party responsible for their design. For every reaction, retain the load case that produced it: combining peak values from different scenarios without justification can change the demand on the beam.
If different teams design the roof, steel structure, and foundation, cross-check their tables and drawings before issuing them. This turns the forum question into a specific verification: can every link transfer the force it receives from the preceding one?